Scenario-based · sanitized

Post-deployment Monitoring Table (sanitized)

Turns 'keep an eye on the model' into executable action. Every row answers five questions: what to watch, how often, who is responsible, what counts as abnormal, and what to do next.

What this artifact is for

A monitoring table is not decoration. It exists to make continuous oversight executable. Each row answers five questions at once: what to watch, how often, who is responsible, what counts as abnormal, and what happens when it does. A metric without a review owner, a trigger threshold, and a required action is not being governed.

The structure and monitoring logic here are the ones I apply in pre-deployment governance design, shown in the domain of my patient-facing cardiometabolic twin to match the bounded cardiometabolic use case in my Viewpoint. Because the system I build has not yet deployed, the worked example is an illustrative post-deployment monitoring plan used to exercise the structure, not figures from a live system. It carries no confidential project or patient detail.

Fixed metadata

Field Value
Data provenance Wearable and EHR streams, model output logs, human review records
Model version Cardiometabolic Risk Twin — pre-deployment build (version pinned at validation before any pilot)
Approval owner AI Governance Lead
Effective date Not yet in force (pre-deployment)
Version v0.2
Last updated July 2026
Known limitation Some performance metrics have label delay; monthly review may lag real clinical change

Monitoring table

What to monitor Metric Frequency Owner Alert threshold Trigger action
Input drift Age, condition mix, missingness, wearable and lab distributions (HR, HRV, sleep, blood pressure, HbA1c) Monthly Data team Significant shift in any key variable Start drift analysis
Output drift High-risk trajectory flags per week Weekly Governance Lead More than 50% above baseline Notify clinical lead for review
Performance drift AUC, sensitivity, calibration for cardiovascular risk Monthly Vendor + data team AUC down > 0.05 or sensitivity down > 15% Submit performance report
Calibration drift Observed vs predicted cardiovascular events in the high-risk group Monthly Patient safety team Predicted high-risk but observed rate keeps falling Recalibrate or restrict use
Fairness drift Performance for women, older, and low-income or LMIC patients Quarterly Ethics / equity committee Miss rate rises notably in any group Subgroup audit
Clinical burden Clinician time handling flags Monthly Clinical unit lead Rising alert-fatigue complaints Adjust thresholds or workflow

The design principle

Monitoring is only real when each metric is tied to an owner, a trigger threshold, and a required action. The table answers the questions that matter after deployment: what do we look at, how often, who is accountable, what counts as abnormal, and what do we do about it. That is the difference between an accuracy report and continuous governance.

Citation metadata
Field Value
Title Post-deployment Monitoring Table (sanitized)
Author Xiaoyan Qian
Public page version v0.2
Publication date 2026-08-03
Stable URL https://xiaoyanqian.com/artifacts/monitoring-table/
Licence All rights reserved
Suggested citation Qian, X. (2026). Post-deployment Monitoring Table (sanitized) (v0.2). https://xiaoyanqian.com/artifacts/monitoring-table/